Ingersoll Rand electric powered vertical and horizontal stationary air compressors. To see our Mi-T-M, Eagle, Ciason and other air compressors, please click on the link below.
|
Model
|
Power
|
CFM*
|
Dimensions Inches
|
Stage
|
Style
|
Weight
|
|
SS3L3
|
3 hp 230V
|
11.3
|
20L x 23W x 66H
|
Single
|
Electric 60 Gallon Vertical
|
300 lbs
|
SS5L5
|
5 hp 230V
|
18.1
|
20L x 23W x 71H
|
Single
|
Electric 60 Gallon Vertical
|
310 lbs
|
|
CFM rating is at 40 psi. These two SS Series compressors require 230 Volt Single Phase Power.
Horsepower ratings are continuous 100% duty cycle.
Cast Iron oil lubricated pump for long service life.
Maximum operating pressure is 135 psi
Horizontal Tank Two Stage
|
Model
|
Power
|
CFM*
|
Dimensions Inches
|
Stage
|
Style
|
Weight
|
|
2340L5
|
5 hp
|
14.7
|
20L x 33W x 69H
|
Two
|
Vert 60 Gallon 1/2" npt Outlet
|
400 lbs
|
2340N5
|
5 hp
|
14.7
|
22L x 36W x 69H
|
Two
|
Vert 80 Gallon 1/2" npt Outlet
|
475 lbs
|
2475N5
|
5 hp
|
16.8
|
26L x 38W x 70H
|
Two
|
Vert 80 Gallon 3/4" npt Outlet
|
500 lbs
|
2475N7.5
|
7.5 hp
|
24.3
|
26L x 38W x 70H
|
Two
|
Vert 80 Gallon 3/4" npt Outlet
|
500 lbs
|
2545E10V
|
10 hp
|
35
|
73L x 28W x 51H
|
Two
|
Horiz 80 Gallon 3/4" npt Outlet
|
835 lbs
|
7100E15V
|
15 hp
|
50
|
72L x 28W x 57H
|
Two
|
Horiz 120 Gallon 1" npt Outlet
|
1000 lbs
|
|
ACFM ratings are at 175 psi and measured at the tank outlet.
5 and 7.5 hp models run on 230 Volt Single Phase 60 hz power.
10 and 15 hp models are available in 200 Volt 3 Phase, 230 Volt 3 Phase, 460 Volt 3 Phase and
575 Volt 3 Phase, 60 hz power. Please specify voltage when ordering.
Compressor pump is oil lubricated. Service life may be twice as long as oil less pumps.
Units are rated for 100% continuous duty cycle. Motor starter is included
Optional items include: Intercooler, low oil pressure shutdown and electric tank drain.
Single Stage or Dual Stage. What's the Difference?
Single stage pumps deliver the air from all cylinders in one cycle. The air goes directly from the
cylinder into the tank. The result is a greater volume of air at the sacrifice of pressure.
Dual or Two stage pumps transfer the air from the primary or low pressure cylinder to the
secondary or high pressure cylinder. The air is further compressed by the high pressure cylinder.
The result is a higher pressure with a sacrifice of volume.
Single stage compressor is designed for uses up to approximately 100 pounds Dual or Two stage compressor is designed for uses up to approximately 175 pounds. The compressors on this page are designed for continuous 100% duty.
|
Need more information? Visit us at our show room in Arizona. Our info number is (480) 838-7472
|